Skip to content
Music×EEG

Figures & diagnostics gallery

Every figure, straight from the reports

53 publication figures reproduced unmodified from reports/. Filter by dataset and topic; open any figure for a zoomable view with its scientific caption. Keyboard: ←→ to step, Esc to close.

Showing 53 of 53 figures

  • MindWaveSignal Processing & Quality

    Butterworth 1–40 Hz filter response

    Magnitude (dB) and phase across 0–60 Hz for the 4th-order zero-phase SOS bandpass. −3 dB cut-offs at 1 Hz and 40 Hz; DC drift suppressed by > 40 dB at 0.2 Hz and mains harmonics by > 30 dB at 50/60 Hz. Identical relative bandwidth at 512 Hz and the decimated 256 Hz rate.

  • MindWaveSignal Processing & Quality

    Raw vs. filtered FP1 traces

    Representative 5-second waveforms for Rest, Medium Math and Hard Math. Filtering removes low-frequency baseline wander without distorting oscillatory bursts such as resting alpha.

  • MindWaveSignal Processing & Quality

    Per-subject signal-quality summary

    Percentage of rejected 1-s chunks per participant under the screening rules. Over 90% of subjects kept a rejection rate below 1%.

  • MindWaveNeurophysiology & Behavior

    Mean power spectrum per task

    Grand-average PSDs (thick) over individual spectra (thin) from 1–45 Hz. Rest shows an 8–12 Hz alpha peak from eyes-closed idling; both math tasks show alpha suppression and elevated theta/beta power.

  • MindWaveNeurophysiology & Behavior

    Key biomarkers by task

    Distributions of six key features across Rest, Medium and Hard Math: strong Rest-vs-Math separation, minimal Medium-vs-Hard separation.

  • MindWaveNeurophysiology & Behavior

    The eyes-closed alpha confound

    Panel A: relative alpha collapses from eyes-closed Rest to eyes-open Medium Math (Δ = −0.1886, d_z = −1.378) and then flatlines between Medium and Hard (Δ = −0.0029, p = 0.2553). Panel B: non-alpha markers (rel_theta, hjorth_complexity) rise progressively with demand.

  • MindWaveMachine Learning & Ablation

    Confusion matrices — Rest/Math, Medium/Hard, 3-class

    Rest vs Math (GroupKFold RF): Rest 62.6% correct, Math 86.8% correct. Medium vs Hard: 43.9% and 64.5% correct — heavy cross-confusion. The 3-class model confuses Medium and Hard extensively.

  • MindWaveMachine Learning & Ablation

    Data-leakage demonstration

    Random chunk-level KFold (leaked) vs subject-grouped GroupKFold (honest). Leakage inflates RF balanced accuracy from 71.78% to 83.12% (+11.33 pp) and LogReg from 71.69% to 76.37% (+4.68 pp).

  • MindWaveMachine Learning & Ablation

    Within-subject permutation null

    200 within-subject label permutations: null mean 0.5084 (SD 0.0039, 95th percentile 0.5145) vs observed 0.7131. Empirical p = 1/201 = 0.0050.

  • MindWaveMachine Learning & Ablation

    Personal-calibration sample efficiency

    First k contiguous chunks per task used for calibration, evaluation strictly on later chunks. k ≤ 20 s degrades performance (−2.4 to −13.6 pp); only k = 40 s yields a net gain (+2.39 pp).

  • MindWaveMachine Learning & Ablation

    TreeSHAP feature importance

    Global ranking over 1,000 evaluation chunks: theta_alpha_beta, theta_beta, rel_theta and hjorth_complexity push toward high load; rel_alpha carries negative SHAP during math (desynchronisation); spec_entropy decreases.

  • PhysioNetSignal Processing & Quality

    Timestamp interval distribution

    Clean 256 Hz raster quantised to alternating 3.0 ms and 4.0 ms intervals, plus the periodic Δt = 0 ms duplicate spike present in A3, A5 and A10.

  • PhysioNetSignal Processing & Quality

    Participant recording timelines

    Continuous EEG coverage across the ~85-minute protocol for all 10 participants: session blocks, 3- and 6-minute rest breaks, manual tags and the reconstructed A8 Session 2 onset.

  • PhysioNetSignal Processing & Quality

    Session & event alignment error

    Sub-sample stimulus-to-EEG alignment error (< 2.0 ms) across participants, and the manual-tag lead (11.2 s) and lag (16.8 s) relative to E-Prime boundary stimuli.

  • PhysioNetSignal Processing & Quality

    Trial event coverage & epoch usability

    Per-participant epoch usability: strictly clean epochs, single-duplicate-sample epochs (A3, A5, A10) and scalp-channel artifact exclusions.

  • PhysioNetSignal Processing & Quality

    4-channel traces with event markers

    Continuous Muse EEG (TP9, AF7, AF8, TP10) with synchronised target/non-target stimulus onsets, response triggers and the 2.0-s epoch window.

  • PhysioNetSignal Processing & Quality

    Raw vs. Track A / Track B filtered traces

    Continuous raw signal against Track A (1–40 Hz, cognitive bandpower) and Track B (0.5–30 Hz, ERP/time-domain) outputs.

  • PhysioNetSignal Processing & Quality

    Dual-track SOS filter responses

    Magnitude and phase for both tracks, with single-pass (~48 dB/oct) and forward-backward (~96 dB/oct) roll-off per transition edge.

  • PhysioNetSignal Processing & Quality

    Continuous PSD before/after filtering

    Welch PSD of the continuous recording showing steep stopband attenuation outside the passband.

  • PhysioNetSignal Processing & Quality

    Channel quality & fallback gains

    Usable rates by channel and the gain from frontal single-channel fallback across the cohort.

  • PhysioNetSignal Processing & Quality

    Cohort channel usability (97.8% frontal yield)

    Retention per scalp channel and overall frontal epoch yield. Mastoid channels suffer temporalis tension; frontal fallback restores 97.8% (13,772 / 14,080) usable trials.

  • PhysioNetSignal Processing & Quality

    Participant data availability

    Total extracted trials (1,408), usable fallback trials and bilateral-intact trials for each participant.

  • PhysioNetSignal Processing & Quality

    Structural feature missingness

    Availability matrix over 500 sampled trials across A1–A10 — e.g. frontal alpha asymmetry is structurally NaN where only one frontal electrode is usable.

  • PhysioNetSignal Processing & Quality

    200 µV vs 300 µV threshold sensitivity

    Relaxing the cut-off from 200 µV to 300 µV adds only 124 trials (+0.88%) and shifts effect sizes by < 0.01 d_z.

  • PhysioNetSignal Processing & Quality

    Cohort sensitivity: N = 10 vs N = 7 effect sizes

    Excluding the duplicate-glitch participants (A3, A5, A10) preserves 100% of effect directions, with |Δd_z| < 0.18.

  • PhysioNetSignal Processing & Quality

    Cohort sensitivity: overlaid distributions

    Feature distributions of the primary (N = 10) and sensitivity (N = 7) cohorts overlaid.

  • PhysioNetNeurophysiology & Behavior

    Accuracy by music condition (fixed order)

    Cohort accuracy across the four sessions: 36.51% → 40.99% → 45.26% → 51.79%. Because every participant ran the same order, this rise is collinear with practice and cannot be attributed to music.

  • PhysioNetNeurophysiology & Behavior

    Reaction time by music condition

    Correct-response latency stays roughly stable (~382–397 ms) across the four conditions; music main effect on RT n.s. (p = 0.1513).

  • PhysioNetNeurophysiology & Behavior

    1-back vs 3-back behavioural contrast

    Participant-level paired lines: d′ drops from 1.817 to 1.110 (F(1,9) = 17.14, p = 0.0025, η²p = 0.656) and accuracy from 48.89% to 38.38% under 3-back load.

  • PhysioNetNeurophysiology & Behavior

    Participant-wise performance

    Individual accuracy across all four conditions — mean accuracy ranges from 3.85% (A6) to 90.77% (A1), highlighting cohort heterogeneity.

  • PhysioNetNeurophysiology & Behavior

    Speed–accuracy trade-off

    Reaction time vs accuracy across conditions and participants.

  • PhysioNetNeurophysiology & Behavior

    Omission rates & RT distribution

    Per-participant omission rates (A4 75.9%, A6 96.2%, A10 95.7%) and the aggregate RT histogram over all valid presses.

  • PhysioNetNeurophysiology & Behavior

    Practice curve vs flat EEG across sessions

    Behavioural accuracy rises across the four fixed-order sessions while EEG rhythms stay flat (no condition difference survives FDR, all q ≥ 0.90) — the signature of a practice effect, not a music effect.

  • PhysioNetNeurophysiology & Behavior

    Paired theta rise, 1-back → 3-back

    Participant-level paired slopes for EEG features. TP10_rel_theta d_z = +1.26 (p = 0.0039 uncorrected). Exploratory: zero of 42 features survive BH-FDR (q ≥ 0.164).

  • PhysioNetNeurophysiology & Behavior

    Frontal theta vs working-memory sensitivity

    Between-subject scatter: mean frontal theta vs d′, Spearman ρ = −0.8788 (p = 0.0008, N = 10). Trait-level association only — within-subject fluctuations do not track performance (|r_rm| < 0.20).

  • PhysioNetNeurophysiology & Behavior

    Frontal EEG features by music condition

    Boxplots of frontal features across the four auditory conditions. No spectral difference survives FDR correction.

  • PhysioNetNeurophysiology & Behavior

    Frontal bandpower by music condition

    Frontal bandpower distributions under No Music, Relaxing, Stressing and AI Music.

  • PhysioNetNeurophysiology & Behavior

    Frontal bandpower by N-back level

    Frontal theta, alpha and beta across 0-, 1-, 2- and 3-back levels.

  • PhysioNetNeurophysiology & Behavior

    Stimulus-locked epochs, 1-back vs 3-back

    Representative 2.0-s stimulus-locked waveforms under low vs high working-memory load.

  • PhysioNetNeurophysiology & Behavior

    Pre- vs post-stimulus features

    Feature distributions for the active pre-stimulus window (−500–0 ms, anticipation under continuous music — not a resting baseline) vs the post-stimulus window.

  • PhysioNetNeurophysiology & Behavior

    Individual differences in frontal rhythms

    Frontal theta and alpha distributions per participant (A1–A10) — the between-subject spread that defeats generic models.

  • PhysioNetNeurophysiology & Behavior

    Frontal feature correlation matrix

    Spearman rank correlations across 17 core frontal rhythm features.

  • PhysioNetMachine Learning & Ablation

    Phase 3C generic model performance

    Dummy, Logistic Regression and Random Forest balanced accuracy under participant-grouped GroupKFold, hovering at the 50% chance line.

  • PhysioNetMachine Learning & Ablation

    Phase 3C confusion matrices (held-out participants)

    Confusion matrices on held-out participants under GroupKFold.

  • PhysioNetMachine Learning & Ablation

    Generic vs personalized accuracy

    Generic All (51.2%), Generic Condition-Matched (50.0%) and Personalized (55.6%) RF balanced accuracy on identical held-out blocks (p = 0.0025, d_z = 1.31, Holm p_adj = 0.0075).

  • PhysioNetMachine Learning & Ablation

    Personalization gain by participant

    Grouped bars per participant — 9 of 10 improve under personalized calibration.

  • PhysioNetMachine Learning & Ablation

    Per-participant calibration delta

    Waterfall of ΔBalAcc = personalized − generic per participant (largest: A7 +9.99, A4 +8.19, A1 +7.50, A3 +6.65 pp; smallest: A2 +0.38 pp).

  • PhysioNetMachine Learning & Ablation

    Calibration budget scaling

    Accuracy across 10/20/30/50% budgets under original partitions and on the fixed common evaluation set (Sessions 3–4): 52.19% → 54.68% → 55.77% → 57.06%. An observed trend, not a proven optimum.

  • PhysioNetMachine Learning & Ablation

    Calibration trials vs held-out accuracy

    Sample-efficiency curve of calibration trial count against held-out accuracy on the common evaluation set.

  • PhysioNetMachine Learning & Ablation

    Feature-group ablation

    Ranking of feature subsystems under personalized calibration: band_ratios first (56.25%), erp last at chance (50.26%).

  • PhysioNetMachine Learning & Ablation

    Normalization strategy comparison

    Raw (53.5%) vs z-score (55.7%) vs MinMax (56.0%), with scalers fit strictly on calibration blocks.

  • PhysioNetMachine Learning & Ablation

    Feature-selection stability

    How often each top feature is selected across participant calibration sets.

  • PhysioNetMachine Learning & Ablation

    Phase 4 confusion matrices

    Side-by-side confusion matrices for generic vs personalized classifiers on held-out blocks.